title: "Tool frames: $MNUTOOL and $MNUTOOLNUM"
description: "What $MNUTOOL and $MNUTOOLNUM hold on a Fanuc controller, and how to read the 10 tool frames (UTOOL) and the active tool from a PC, in C# or Python."
---

# Tool frames: $MNUTOOL and $MNUTOOLNUM

Where does a Fanuc controller store its tool frames, and how do you read the TCP of every tool from a PC? The tool frames are the system variable `$MNUTOOL`, and the active tool is `$MNUTOOLNUM`. Both are in the file `sysframe.va`.

## The variables

| Variable | Type | Meaning | File |
| --- | --- | --- | --- |
| `$MNUTOOL[g,n]` | POSITION | Tool frame n of motion group g: X, Y, Z, W, P, R. n is 1 to 10 on a standard controller | `sysframe.va` |
| `$MNUTOOLNUM[g]` | BYTE | Number of the active tool of group g | `sysframe.va` |

In a TP program, `UTOOL_NUM=2` selects tool 2. The variable `$MNUTOOLNUM[1]` tells which tool is active, for example to copy it in a register: `R[1]=$MNUTOOLNUM[1]`.

![The ten tool frames of group 1 and the active one.](/fanuc/documentation/diagrams/utool-array.svg)

## Read every tool in one request

`GetSysframeFile()` reads `sysframe.va` once and returns the tools and the user frames of every group. Then `ReadVariable` reads the active tool by name, through the web server of the controller.

**C# : ToolFrameUtool**
```csharp
using System;
using UnderAutomation.Fanuc;
using UnderAutomation.Fanuc.Common;
using UnderAutomation.Fanuc.Common.Files.Variables;

public class ToolFrameUtool
{
    static void Main()
    {
        FanucRobot robot = new FanucRobot();
        var parameters = new ConnectionParameters("192.168.0.1");
        parameters.Ftp.Enable = true;
        parameters.Cgtp.Enable = true;
        robot.Connect(parameters);

        /**/
        // sysframe.va holds every tool of every group: one read
        SysframeFile frames = robot.Ftp.KnownVariableFiles.GetSysframeFile();

        // .NET arrays start at 0: $MNUTOOL[1,n] is Mnutool[0, n - 1]
        int active = frames.Mnutoolnum[0];
        for (int n = 1; n <= frames.Mnutool.GetLength(1); n++)
        {
            CartesianPositionVariable t = frames.Mnutool[0, n - 1];
            if (t == null) continue; // uninitialized in the file
            string mark = n == active ? " <- active" : "";
            Console.WriteLine($"UTOOL {n}: X={t.X} Y={t.Y} Z={t.Z} W={t.W} P={t.P} R={t.R}{mark}");
        }

        // Active tool now, read by name through the web server
        int activeNow = robot.Cgtp.ReadVariable("$MNUTOOLNUM[1]").IntegerValue;
        /**/
    }
}
```

**Python : ToolFrameUtool**
```python
from underautomation.fanuc.fanuc_robot import FanucRobot
from underautomation.fanuc.connection_parameters import ConnectionParameters

robot = FanucRobot()
parameters = ConnectionParameters("192.168.0.1")
parameters.ftp.enable = True
parameters.cgtp.enable = True
robot.connect(parameters)

##
# sysframe.va holds every tool of every group: one read
frames = robot.ftp.known_variable_files.get_sysframe_file()

# Python gives one flat list, group 1 first: tools 1 to 10 of group 1
per_group = len(frames.mnutool) // len(frames.mnutoolnum)
active = frames.mnutoolnum[0]
for n, t in enumerate(frames.mnutool[:per_group], start=1):
    mark = " <- active" if n == active else ""
    print(f"UTOOL {n}: X={t.x} Y={t.y} Z={t.z} W={t.w} P={t.p} R={t.r}{mark}")

# Active tool now, read by name through the web server
active_now = robot.cgtp.read_variable("$MNUTOOLNUM[1]").integer_value
##
```

The .NET array starts at 0: `$MNUTOOL[1,3]` is `Mnutool[0, 2]`. In Python, `mnutool` is one flat list with the tools of group 1 first.

## Read or write one tool with RMI

With the RMI option (R912), `ReadUTool(n)` reads one tool and `WriteUTool(n, frame)` writes it. `GetUFrameUTool()` gives the active numbers.

**C# : RmiFramesIoFrames**
```csharp
using System;
using UnderAutomation.Fanuc;
using UnderAutomation.Fanuc.Common;
using UnderAutomation.Fanuc.Rmi.Data;

public class RmiFramesIoFrames
{
    static void Main()
    {
        FanucRobot robot = new FanucRobot();
        ConnectionParameters parameters = new ConnectionParameters("192.168.0.1");
        parameters.Rmi.Enable = true;
        robot.Connect(parameters);

        /**/
        // Read UFRAME 1
        RmiIndexedFrameResponse uf = robot.Rmi.ReadUFrame(1);
        Console.WriteLine($"UFrame 1: X={uf.Frame.X:F1}  Y={uf.Frame.Y:F1}  Z={uf.Frame.Z:F1}");

        // Write UFRAME 1
        robot.Rmi.WriteUFrame(1, new XYZWPRPosition { X = 100, Y = 0, Z = 0, W = 0, P = 0, R = 0 });

        // Read UTOOL 1
        RmiIndexedFrameResponse ut = robot.Rmi.ReadUTool(1);
        Console.WriteLine($"UTool 1: X={ut.Frame.X:F1}  Y={ut.Frame.Y:F1}  Z={ut.Frame.Z:F1}");

        // Write UTOOL 1
        robot.Rmi.WriteUTool(1, new XYZWPRPosition { X = 0, Y = 0, Z = 200, W = 0, P = 0, R = 0 });

        // Get current UFRAME and UTOOL numbers
        RmiUFrameUToolNumbersResponse current = robot.Rmi.GetUFrameUTool();
        Console.WriteLine($"Active UFRAME={current.Frame}  UTOOL={current.Tool}");

        // Set the active UFRAME and UTOOL
        robot.Rmi.SetUFrameUTool(uframe: 1, utool: 2);
        /**/

        robot.Disconnect();
    }
}
```

**Python : RmiFramesIoFrames**
```python
from underautomation.fanuc.fanuc_robot import FanucRobot
from underautomation.fanuc.connection_parameters import ConnectionParameters
from underautomation.fanuc.common.xyzwpr_position import XYZWPRPosition

robot = FanucRobot()
parameters = ConnectionParameters("192.168.0.1")
parameters.rmi.enable = True
robot.connect(parameters)

##
# Read UFRAME 1
uf = robot.rmi.read_u_frame(1)
print(f"UFrame 1: X={uf.frame.x:.1f}  Y={uf.frame.y:.1f}  Z={uf.frame.z:.1f}")

# Write UFRAME 1
frame_pos = XYZWPRPosition()
frame_pos.x = 100
robot.rmi.write_u_frame(1, frame_pos)

# Read UTOOL 1
ut = robot.rmi.read_u_tool(1)
print(f"UTool 1: X={ut.frame.x:.1f}  Y={ut.frame.y:.1f}  Z={ut.frame.z:.1f}")

# Write UTOOL 1
tool_pos = XYZWPRPosition()
tool_pos.z = 200
robot.rmi.write_u_tool(1, tool_pos)

# Get current UFRAME and UTOOL numbers
current = robot.rmi.get_u_frame_u_tool()
print(f"Active UFRAME={current.frame}  UTOOL={current.tool}")

# Set the active UFRAME and UTOOL
robot.rmi.set_u_frame_u_tool(uframe=1, utool=2)
##

robot.disconnect()
```

See [RMI frames, I/O & status](/fanuc/documentation/rmi-frames-io).

## Over a fleet

The same read on every robot gives the tools of a whole plant and shows a tool that somebody changed. See [Back up and compare the frames of a fleet](/fanuc/documentation/fanuc-backup-compare-frames-fleet).

## Cautions

- A taught point keeps the number of its tool, not the values of the tool. Change the tool frame and the robot goes somewhere else for every Cartesian point taught with this tool. Check the programs at low speed after a change.
- A tool overwritten by mistake is a classic. Keep a copy of `sysframe.va` before any change, so that the old values can be read again.
- `sysframe` belongs to one robot. Do not load it on another robot to copy one tool: write the 6 values of that tool instead.

## Without code

[TouchUp](/touchup), the robot workbench for VS Code, shows the tools 1 to 10 and the active tool of a connected Fanuc controller, or of a backup, as a table and in 3D. It reads them only: it does not write a tool frame in this version. See [User frames and tools](/touchup/documentation/user-frames-and-tools).

## See also

- [Fanuc system variables list](/fanuc/documentation/fanuc-system-variables-list)
- [User frames: $MNUFRAME and the active UFRAME](/fanuc/documentation/fanuc-user-frame-uframe)
- [Diagnostics & variables (FTP)](/fanuc/documentation/ftp-diagnostics)
- [Frames & orientations](/fanuc/documentation/motion-frames-orientations)