This page explains the Data panel and the I/O panel of a controller: a table of registers or signals that you read, edit and write back. It applies to Fanuc and Yaskawa controllers. Reading is free. Writing needs the Pro edition, see [Editions and license](/touchup/documentation/license).

## What the panels are

Each controller has a **Data panel** and an **I/O panel**. Both open as a tab of the editor, with a table of 50 rows of one kind. The I/O panel of a Yaskawa controller is different: it is the table of the manuals, see [The I/O panel of a Yaskawa controller](#the-io-panel-of-a-yaskawa-controller). A row has a reference, a value, a comment (or a name on Yaskawa) and an `Add to Watch` button.

The panels replace the Registers, Variables, I/O and Tasks views of the side bar, which are gone: the side bar keeps Controllers, Watch, Toolbox, Backups and Account. See [Read live values](/touchup/documentation/live-values). The panels edit many values at once, with one confirmation.

### Open a panel

Open the nodes of the controller in the Controllers view:

| Brand | Data panel | I/O panel |
| --- | --- | --- |
| Fanuc | `Data` > `Registers`, `Position Registers`, `String Registers`, `KAREL Vars`, `KAREL Positions` | `I/O` |
| Yaskawa | `Data` > `Byte`, `Integer`, `Double`, `Real`, `String`, `Position`, `Base Position`, `External Position` | `I/O` |

`Data` > `Variable Map` opens the Variable Map, see [Navigate across a robot](/touchup/documentation/navigate-a-robot#variable-map). The Fanuc node `Variables` opens the Variables panel, see [Read live values](/touchup/documentation/live-values#variables).

A panel is named after the node and the controller, for example `Data: Cell 3 Fanuc`.

![The Data panel of a Fanuc controller: the numeric registers R[1] to R[50].](/touchup/documentation/screenshots/data-panel.png)

### Choose what to show

| Control | What it does |
| --- | --- |
| `Kind` | The list of kinds of the panel, for example `R · Numeric registers` on Fanuc or `DI · Digital inputs` in the I/O panel |
| `Previous 50`, `Next 50` | Show the 50 values before or after the current page |

The I/O panel of a Yaskawa controller has its own controls, see below.

The values are read again every second while the panel is visible. When you hide the tab, TouchUp stops reading. A register that the controller does not have shows `is not in the scenario` in orange, with no value.

## Edit values

You can change several values, check them, then write them in one step. Nothing is sent to the controller until you click the write button.

1. Click a cell and type the new value.
2. Press `Enter`, or click another cell. The new value is kept as a **pending change**.
3. Repeat for the other cells.
4. Click `Write N changed values`.

`N` is the number of changed cells. A value and a comment of the same row count as two.

![Two pending changes: the value and the comment of R[1]. Each edited cell has a blue bar and a small Revert button that shows the value read from the controller.](/touchup/documentation/screenshots/data-panel-edit.png)

An edited cell has a blue bar on its left. Beside it, a small `Revert` button shows the value read from the controller, for example `↶ 7`. The columns and the rows keep their size when you edit.

| Action | What it does |
| --- | --- |
| `Escape` while you type | Puts the cell back, nothing is kept |
| `Revert` (the small button of the cell) | Drops the pending change of one cell and brings back the value read |
| `Revert All` | Drops every pending change of the panel |

### Write the changes

`Write N changed values` sends only the changed values. TouchUp asks **one confirmation** for the whole panel. It lists each value with its old and new value. After `Confirm`:

- TouchUp reads each value again and shows the value that the controller holds.
- Each register or signal has its own record in the audit log.
- For a Yaskawa name, TouchUp first saves a copy of the name file of the controller. See [Names](#names).
- A value that the controller refuses stays pending. Its row shows `Not written` under the reference, and the reason is the tooltip of that text. The other values are still written.

Fix the cause of a refused value, then click the write button again. A pending change that you make while the confirmation is open is not sent. It stays pending.

The pending changes are kept in the panel only. When you close it, they are lost.

### Free and Pro

A Free user can read and edit the cells. `Write N changed values` opens the Pro dialog and sends nothing. The pending changes stay in the panel.

## Cells that cannot be edited

A read-only cell has no field. It shows a few words that say why, for example `Simulate it to edit` or `Set by its device`. Point at the words to read the full sentence in a tooltip.

| Cell | Why |
| --- | --- |
| A KAREL position of a Fanuc controller | It is shown, not edited, in the panel |
| A position register or a Yaskawa position (`P`, `BP`, `EX`) | A position has several values. Click `Open` to edit it in the [Position Editor](/touchup/documentation/position-editor), where a Fanuc position register can also change its form |
| The name of a Yaskawa register (`M000` to `M999`) or of a signal that has no user name | These have no name on the controller. See [Names](#names) |
| A Yaskawa signal that is not a network input | See [The I/O panel of a Yaskawa controller](#the-io-panel-of-a-yaskawa-controller). The words beside the value say who sets it, for example `Set by its device` |
| The value of a Fanuc input | An input is set by its device. It takes a value once it is simulated |

When nothing can be written now, the panel says it once, in one line above the table: the controller is not connected, or it or its connection does not allow a write. The cells then show their values with no repeated reason. Point at a cell to read the line again in a tooltip.

## Add to Watch

The `Add to Watch` button of a row adds that register or signal to the Watch view, for this controller. See [Read live values](/touchup/documentation/live-values#watch).

## The I/O panel

The I/O panel shows signals of one kind: `DI`, `DO`, `RI`, `RO`, `GI`, `GO`, `AI`, `AO`, `UI`, `UO`, `SI`, `SO` and flags on Fanuc, and the table of the manuals on Yaskawa. The comment of a Fanuc signal can be edited like a value.

![The I/O panel of a Fanuc controller: the digital inputs, one of them simulated.](/touchup/documentation/screenshots/io-panel.png)

### Simulate a Fanuc signal

The Simulation column shows the state of each signal and two buttons.

| Button | What it does |
| --- | --- |
| `Simulate` | Simulates the signal. Its value can then be edited |
| `Unsimulate` | Puts the signal back under the control of its device |

Simulate and Unsimulate are **actions**, not pending changes. Each one asks its own confirmation and runs at once. They do not count in `Write N changed values`.

- The state is `Simulated`, or `Unknown` when TouchUp does not know it. A real Fanuc controller shows `Unknown` until its SDK reports the state.
- An input takes a value only while it is simulated. Until then, its cell says `Simulate it to edit`.
- The signals `F`, `UI`, `UO`, `SI` and `SO` cannot be simulated (the controller gives a flag no simulation status). Their buttons are disabled.

## The I/O panel of a Yaskawa controller

The I/O panel of a Yaskawa controller is the table of the I/O manuals: every relay number, with its logical name, its name, the name that you gave to it on the controller and its classification. After the relays, it lists the registers `M000` to `M999`. It has no simulation. It replaces the four kinds `IN#`, `OT#`, `IG#` and `OG#` of the previous version.

### Filter, search and sort

| Control | What it does |
| --- | --- |
| `Classification` | Keeps one classification of the manuals, for example `General purpose input`, `Network input`, `Specific input`, `Auxiliary relay` or `Control status`. `All` shows everything |
| `Layer` | Keeps one layer: `Logic I/O`, `Physical I/O`, `Internal` or `Hard signal monitor` |
| `Search` | Looks for a relay number (`80173`), a register (`M010`), a logical name (`SIN#001` or `SIN#(1)`, `IN#(9)`) or a part of a name of the I/O signal catalog. On a connected controller it does not look in the user names, see [Names](#names) |
| `Sort` | `Address`, or `Type, then address` |
| `Previous`, `Next` | Show the previous or next 6 channels. The range, for example `Channels 1 to 6 of 120`, is beside them |

### Channels and signals

The table has one line per **channel**: a channel is the group of 8 signals of one byte, for example channel `4001` holds the relays `40010` to `40017`. The line gives the classification, the layer and the state of the 8 bits, for example `0:1 1:0 2:0 ...`.

Click `Channel <number>` to open the line. It shows one row per signal:

| Column | What it shows |
| --- | --- |
| `Signal` | The relay number, for example `40010` |
| `Logical` | The logical name, for example `SIN#001` |
| `Name in the catalog` | The name of the signal in the I/O signal catalog of TouchUp, its use, and the names it has in other applications or controller generations when they differ |
| `User name` | The name that you gave to the signal on the controller, see [Names](#names) |
| `Classification` | The classification of the manuals |
| `Value` | The value read from the controller |
| `Actions` | `Add to Watch` |

A search opens every channel that it lists, and marks the signals that it found. Without a search, the channels are closed.

![The I/O panel of a Yaskawa controller: a search opens the channels it lists, each signal with its logical name, its name and its classification.](/touchup/documentation/screenshots/io-panel-yaskawa.png)

### Registers

The registers `M000` to `M999` come after the relays, in lines of 8 registers: `Registers M000`, `Registers M008`, and so on. The line shows the 8 values, and opens like a channel to one row per register. A register is a whole number of 16 bits, from -32768 to 32767. It has no relay number, no logical name and no name in the catalog. The classification tells its kind: general purpose, analog output, analog input or system register. Search `M010` to open the line of that register.

![A search on M010 opens the line of the registers M008 to M015.](/touchup/documentation/screenshots/io-panel-yaskawa-registers.png)

### Values and writes

TouchUp reads the 6 channels of the page, as long as the panel is visible. When the controller is not connected, the table lists the signals with their names and their classification, without a value.

- A **network input** (relays `27010` to `29567`) and a **general purpose register** (`M000` to `M559`) are edited like any other value: the edit becomes a pending change, and `Write N changed values` writes it after the usual confirmation. A register takes a whole number from -32768 to 32767. See [Edit values](#edit-values) and [Write values and control a program](/touchup/documentation/write-and-control).
- Every other signal is read-only: the analog output registers (`M560` to `M599`), the analog input registers (`M600` to `M639`), the system registers (`M640` to `M999`) and every relay that is not a network input. The words beside its value say who sets it, and the tooltip gives the full reason.

### Names

The column `Name in the catalog` gives the names of the I/O signal catalog. It is read-only.

The column `User name` gives the names that you gave to the general purpose signals on the controller (`IN#(n)` and `OT#(n)`). The user names come from `IONAME.DAT` of the controller. You can edit them here. The registers and the other signals (network, external, specific) have no user name: their cell is read-only, with the reason beside it.

![The channel of the relay 00010: the column User name gives the names of the controller, in a field that you can edit.](/touchup/documentation/screenshots/io-panel-yaskawa-names.png)

- On a connected controller, TouchUp reads `IONAME.DAT` once, when it connects. A name that you change on the pendant shows after a new connection. When the controller refuses the file, the column stays empty and the panel shows no error.
- On a connected controller, the search does not look in the user names. Search the relay or the logical name, then read the name in the column.
- In the panel of a backup, the search looks in the user names too, see [Open the I/O panel of a backup](/touchup/documentation/backup#open-the-io-panel-of-a-backup).
- The names of the external signals (`EXIONAME.DAT`) are not shown.

### Edit a name

The name of a Yaskawa variable (`B`, `I`, `D`, `R`, `S`, `P`, `BP`, `EX`, column `Name` of the Data panel) and the user name of a general purpose signal (column `User name` of the I/O panel) are edited like a value, see [Edit values](#edit-values).

1. Click the name, type the new one and press `Enter`. The name becomes a pending change, and a small `Revert` button beside it shows the name read from the controller.
2. Click `Write N changed values` and `Confirm`. A name and a value are written in the same step.

![The name of the relay 00010 changed to PART IN PLACE: a pending change, with a small Revert button that shows the name read from the controller, and the button Write 1 changed value.](/touchup/documentation/screenshots/io-panel-yaskawa-name-edit.png)

A name follows the rules of the controller files:

- 16 characters at most, printable ASCII only: letters, digits, spaces and signs.
- No comma, because it separates the names in `IONAME.DAT`.
- It does not start with `/`, which marks a section title of the file.
- An empty name clears the name.

A name that breaks a rule is refused with its reason, and nothing is sent to the controller.

Before it writes, TouchUp saves a copy of the name file that it will replace: `VARNAME.DAT` for a variable, `IONAME.DAT` for a signal. The audit record of the write points to that copy, see [Write values and control a program](/touchup/documentation/write-and-control). The write replaces the whole file: a name that someone changes on the pendant between the moment you click `Confirm` and the end of the write is lost.

The write needs the Pro edition, like a value, see [Free and Pro](#free-and-pro). When the controller or its connection does not offer the way to write names, TouchUp refuses the name and says that the function is not available, with the reason. The position value of a `P`, `BP` or `EX` variable stays read-only, only its name can be edited.

### From a backup

The same table opens from a backup, without a controller. See [Open the I/O panel of a backup](/touchup/documentation/backup#open-the-io-panel-of-a-backup).

## What to read next

- [Read live values](/touchup/documentation/live-values)
- [Write values and control a program](/touchup/documentation/write-and-control)
- [Edit a position](/touchup/documentation/position-editor)
- [Open controller files](/touchup/documentation/controller-files)
- [Back up a controller](/touchup/documentation/backup)