Read the inputs and write the outputs of Fanuc, Yaskawa, Universal Robots, ABB and Stäubli controllers with one code: signal names of each brand, brand support table, C# and Python examples.

  • Prerequisites
  • Brand support
  • Example
  • Read an input and write an output on each controller of a cell
  • Group and analog signals
  • What changes from one brand to another
  • Errors
  • What to read next

This article shows how to read the inputs and write the outputs of Fanuc, Yaskawa, Universal Robots, ABB and Stäubli controllers from a PC, with one code in C# or Python. Only the address of the controller and the native name of the signal change from one brand to another: the table at the end gives the names of each brand.

Prerequisites

  • UnderAutomation.Robotics in your project. See Get started with .NET or Get started with Python.
  • The connection settings of each controller. See Connect to your robot.
  • The license of each brand you connect, or the 30 day trial. See Licensing.
  • The native name of each signal, the one of the pendant and the programs. See the table at the end.
  • An output is connected to the cell. Writing it can start a machine, close a gripper or open a valve. Check what the signal does before you write it, and test on a simulator first.

Brand support

Each cell gives the protocol that the method uses on this brand, in the default order. The table is generated from the route data of the library. "Not available" means that the brand has no route for the method: the call throws FeatureNotSupportedException, and IsAvailable returns false before the call. (manual) marks a route that you enable yourself in the connection parameters.

Inputs and outputs
MethodFanucYaskawaUniversal RobotsABBStäubli
Io.ReadSNPX, CGTP (Cgtp)High Speed Ethernet Server, Ethernet ServerRTDE, Primary Interface (Primary)Robot Web ServicesSOAP
Io.WriteBooleanSNPX, CGTP (Cgtp), CGTP (CgtpKcl), TelnetHigh Speed Ethernet Server, Ethernet ServerPrimary Interface (Script), Interpreter Mode (manual)Robot Web ServicesSOAP
Io.WriteNumberSNPX, CGTP (Cgtp), CGTP (CgtpKcl), TelnetHigh Speed Ethernet Server, Ethernet ServerPrimary Interface (Script), Interpreter Mode (manual)Robot Web ServicesSOAP
Methods of this article3 of 33 of 33 of 33 of 33 of 3

Example

Read an input and write an output on each controller of a cell

The example connects to the controllers of a cell one after the other. It reads one input and switches one output on. Read returns an IoValue: IsOn is true when the signal is on, or when its number is not 0. WriteBoolean writes a digital signal.

static void Main()
{
// One line per controller: the brand, the address, an input and an output, with their native names
var cell = new[]
{
(Brand: "fanuc", Address: "192.168.0.1", Input: "DI[1]", Output: "DO[1]"),
// Yaskawa: #27010 is a network input, the only kind of signal that the controller accepts to write by default
(Brand: "yaskawa", Address: "192.168.0.2", Input: "IN#(1)", Output: "#27010"),
(Brand: "universalrobots", Address: "192.168.0.3", Input: "DI0", Output: "DO0"),
(Brand: "abb", Address: "192.168.125.1", Input: "DI_PartPresent", Output: "DO_Gripper"),
(Brand: "staubli", Address: "192.168.0.254", Input: @"BasicIO-1\%I0", Output: @"BasicIO-1\%Q0"),
};
foreach (var controller in cell)
{
// The same code for each controller of this cell
RobotController robot = new RobotController();
robot.Connect(RobotConnectionParameters.Create(controller.Brand, controller.Address));
IoValue input = robot.Io.Read(controller.Input);
Console.WriteLine($"{robot.Brand} {input.Name}: {(input.IsOn ? "on" : "off")}");
// An output acts on the cell: check what it does before you write it
robot.Io.WriteBoolean(controller.Output, true);
robot.Disconnect();
}
}
}
Click to see the full code

In Python, the names are in snake_case: robot.io.read(...), robot.io.write_boolean(...). A Stäubli name contains a backslash: write it with a verbatim string in C# (@"BasicIO-1\%I0") and a raw string in Python (r"BasicIO-1\%I0").

Group and analog signals

Number of an IoValue gives the integer of a group signal and the value of an analog signal. WriteNumber writes them. This example uses the signals of a Fanuc controller: on another brand, give the names of the table below.

RobotController robot = new RobotController();
robot.Connect(RobotConnectionParameters.Create("fanuc", "192.168.0.1"));
robot.Io.WriteBoolean("DO[1]", true);
robot.Io.WriteNumber("GO[1]", 5);
robot.Disconnect();
}
Click to see the full code

What changes from one brand to another

The code does not change. The name of the signal follows the syntax of the controller, and some brands accept the write of some signals only.

BrandNative nameExamplesBefore a writeBrand article
FanucKind of signal and index, as the pendant writes it. A comment can follow the index after :.DI[1], DO[1], RI[1], RO[1], UI[1], UO[1], GI[1], GO[1], AI[1], AO[1], F[1]To give an input a value of your own, simulate it first. See Io.Set and simulate inputs and outputs
YaskawaGeneral purpose signals IN#(n) and OT#(n), groups of 8 signals IG#(n) and OG#(n), or a contact number.IN#(1), OT#(3), IG#(1), OG#(2), #10010, #27010By default, the controller accepts the write of the network inputs only (#27010 to #29567).Read and write IO
Universal RobotsName of the I/O tab of PolyScope.DI0 to DI7, DO0 to DO7, CI0 to CI7, CO0 to CO7, TI0, TI1, TO0, TO1, AI0, AI1, AO0, AO1The default write route sends a script: the program that runs on the robot stops. On e-Series and PolyScope X, the robot is in remote control.Read and write IO
ABBName of the signal in the I/O configuration of the controller.DI_PartPresent, DO_GripperThe user of the connection has the write grant.Read and write IO signals
StäubliBoard and I/O, separated by a backslash. The boards depend on the configuration of the controller.BasicIO-1\%I0, BasicIO-1\%Q0The user of the connection has the right to write the output.Read and write IO

On Yaskawa, the controller writes 8 signals at a time. The library reads the byte of the signal, changes the signal and writes the byte back. A signal of the same byte that the ladder, a job or another client changes between the read and the write gets its old value back.

The names of your cell can differ from these examples. robot.Io.List(kind) gives the signals of one kind with their names, on the brands that have this method: see Io.

Errors

  • FeatureNotSupportedException: the brand has no route for the method.
  • RouteUnavailableException: the method has routes, but none can be used, for example because the protocol did not answer at the connection.
  • ControllerRefusedException: the controller received the write and refused it.
  • ArgumentException: the name does not follow the syntax of the brand. The message gives the expected syntax.

The page Errors explains each exception.

What to read next

  • Io: comments, lists, reads of several signals and simulation.
  • Read and write robot variables: the variables of the brands that have them.