UnderAutomation
Une question ?

[email protected]

Contactez-nous
UnderAutomation
⌘Q
Cette page est disponible uniquement en anglais.

Read and write I/O

Read and write the digital and analog I/O of a UR cobot in C# or Python, with RTDE and its masks, or with the Primary Interface.

  • The I/O of the controller
  • Which way to choose
  • Prerequisites
  • Example
  • Read a bit
  • Write with a mask
  • Troubleshooting
  • What to read next

This article shows how to read and write the digital and analog I/O of a Universal Robots cobot from a PC, in C# or Python. It compares RTDE, the Primary Interface and URScript, and gives a complete program.

The I/O of the controller

I/ONumbersRTDE bits
Standard digital0 to 70 to 7
Configurable digital0 to 78 to 15
Tool digital0 to 116 to 17
Standard analog0 to 1
Tool analog0 to 1

Which way to choose

WayReadWriteFrequency
RTDEActualDigitalInputBits, ActualDigitalOutputBits, StandardAnalogInput0...StandardDigitalOutput, ConfigurableDigitalOutput, StandardAnalogOutput0..., with a maskUp to 500 Hz
Primary InterfaceMasterboardData.DigitalInputs, DigitalOutputs, AnalogInput0..., ToolDataURScript set_standard_digital_out... in a secondary program10 Hz

RTDE is the way for a fast or frequent access. The Primary Interface needs no setup: it is enabled by default.

Prerequisites

  • The service RTDE (or Primary Client Interface) is enabled on the robot: see Prepare the robot.
  • To write, the robot is in remote control on e-Series and PolyScope X.
  • When the robot program also writes an output, decide which side owns it: the last write wins.

Example

The program reads the inputs with RTDE, sets output 2 and resets output 5, then does the same with URScript.

using UnderAutomation.UniversalRobots;
using UnderAutomation.UniversalRobots.Rtde;
class HowToReadWriteIo
{
static void Main(string[] args)
{
var robot = new UR();
var parameters = new ConnectParameters("192.168.0.1");
parameters.Rtde.Enable = true;
parameters.Rtde.Frequency = 125;
// Read: bits 0-7 standard, 8-15 configurable, 16-17 tool
parameters.Rtde.OutputSetup.Add(RtdeOutputData.ActualDigitalInputBits);
parameters.Rtde.OutputSetup.Add(RtdeOutputData.ActualDigitalOutputBits);
parameters.Rtde.OutputSetup.Add(RtdeOutputData.StandardAnalogInput0);
// Write: a mask selects the outputs, a value sets them
parameters.Rtde.InputSetup.Add(RtdeInputData.StandardDigitalOutputMask);
parameters.Rtde.InputSetup.Add(RtdeInputData.StandardDigitalOutput);
robot.Connect(parameters);
Thread.Sleep(200);
// Read the inputs and the outputs
ulong inputs = robot.Rtde.OutputDataValues.ActualDigitalInputBits;
bool di3 = (inputs >> 3 & 1) == 1;
bool configurableDi0 = (inputs >> 8 & 1) == 1;
double ai0 = robot.Rtde.OutputDataValues.StandardAnalogInput0; // A or V
Console.WriteLine($"DI3={di3} CI0={configurableDi0} AI0={ai0:F3}");
// Set DO2 and reset DO5. The other outputs do not change
var values = new RtdeInputValues();
values.StandardDigitalOutputMask = (1 << 2) | (1 << 5);
values.StandardDigitalOutput = 1 << 2;
robot.Rtde.WriteInputs(values);
// The same with the Primary Interface, in a secondary program:
// the running program does not stop
robot.PrimaryInterface.Script.Send(
"sec setOutputs():\n" +
" set_standard_digital_out(2, True)\n" +
" set_standard_digital_out(5, False)\n" +
"end\n");
// Read with the Primary Interface, 10 times per second
bool di0 = robot.PrimaryInterface.MasterboardData.DigitalInputs.Digital0;
bool toolDi1 = robot.PrimaryInterface.MasterboardData.DigitalInputs.ToolDigital1;
robot.Disconnect();
}
}

Read a bit

ActualDigitalInputBits holds all the digital inputs in one integer: bit n is (bits >> n) & 1. The masterboard data of the Primary Interface gives each bit as a property: Digital0 to Digital7, Configurable0 to Configurable7, ToolDigital0 and ToolDigital1.

Write with a mask

An RTDE write changes only the outputs of the mask. StandardDigitalOutputMask = 0b0010_0100 selects outputs 2 and 5; StandardDigitalOutput = 0b0000_0100 sets 2 and resets 5. The analog outputs have their own mask, StandardAnalogOutputMask.

Troubleshooting

  • The output does not change: the robot is not in remote control, or the robot program writes the same output.
  • The output changes, then goes back: the robot program, or an I/O action of the installation, writes it.
  • The running program stops: URScript was sent without sec. A line or a def program replaces the running program.

What to read next

  • RTDE: the setup and the masks.
  • Read and write registers: exchange numbers with the robot program.

Intégrez facilement les robots Universal Robots, Fanuc, Yaskawa, ABB ou Staubli dans vos applications .NET, Python, LabVIEW ou Matlab

UnderAutomation
Contactez-nousLegal