Prepare a Fanuc controller

The network, the ports, the FTP user, the SNPX option and the ROBOGUIDE workcell that TouchUp needs to connect to a Fanuc controller.

  • Network
  • Protocols
  • Web server and FTP
  • SNPX
  • Program transfer
  • ROBOGUIDE
  • What to read next

This page lists what a Fanuc controller and the network need before TouchUp connects to it, for a real controller and for ROBOGUIDE. TouchUp uses the web server, FTP and SNPX of the controller.

Network

  • The PC and the controller are on the same network, and the controller answers a ping from the PC.
  • The firewalls between the PC and the controller let the ports of the protocols through: 80 or 3080 (web server), 21 (FTP), 60008 (SNPX).
  • When ICMP is blocked on the network, turn off the ping before connect in the options of the controller: otherwise the connection fails at once.

Protocols

Web server and FTP

No controller option is needed. The web server gives the variables and the I/O from firmware V8.30, the programs and the positions from V9.10.

The FTP account decides the rights. Without a user, the controller logs in at the OPERATOR level and can answer "Operation password protected", for example to a program upload. Enter a user of a higher level, such as INSTALL, in the guide Add a controller or with Edit Controller.

SNPX

With the FANUC America parameters (R650 FRA), SNPX needs the option R553 "HMI Device SNPX". With the FANUC Ltd. parameters (R651 FRL), no option is needed. TouchUp uses SNPX when it answers, and works without it.

Program transfer

To send a .ls program as text, the controller needs the ASCII Upload option (R507 or R796). It is not a condition to connect. See Send a file to the controller.

ROBOGUIDE

  • The virtual controller is started and the workcell is open.
  • In the guide Add a controller, click Browse to a ROBOGUIDE robot... and choose services.txt in the folder of the robot in the workcell (<workcell folder>\Robot_1 by default). TouchUp reads the ports there and connects to 127.0.0.1.
  • When ROBOGUIDE runs on another PC, share the folder of the workcell and allow the ports of services.txt in the firewall of that PC.
  • The options, for example R553 with R650 for SNPX, are chosen when the workcell is created.

What to read next

  • Connect to your first controller
  • When the connection fails