Speed override: $MCR.$GENOVERRIDE

Read and set the general speed override $MCR.$GENOVERRIDE of a Fanuc robot from a PC, lock the override keys of the pendant with $GENOV_ENB, and watch it over a fleet.

  • The variables
  • Read, set and lock the override
  • Watch it over a fleet
  • Cautions
  • See also

$MCR.$GENOVERRIDE is the speed override of a Fanuc robot: the % that the operator sets with the +% and -% keys of the pendant. A PC or a line controller can read it, set it back to 100 % at the start of production, and lock the keys.

The variables

VariableTypeMeaningFile
$MCR.$GENOVERRIDEINTEGERGeneral override, the % shown on the pendant. Accepts 1 to 100sycldint.va
$GENOV_ENBBOOLEANFALSE locks the +% and -% keys of the pendant. Set it back to TRUE to unlock themsystem.va

$MCR.$GENOVERRIDE is an integer. Read and write it as an integer, not as a real.

Read, set and lock the override

SNPX reads and writes a system variable in about 2 ms, without any program on the robot.

parameters.Snpx.Enable = true;
robot.Connect(parameters);
// $MCR.$GENOVERRIDE is an INTEGER: the % shown on the pendant
int percent = robot.Snpx.IntegerSystemVariables.Read("$MCR.$GENOVERRIDE");
if (percent < 100)
{
Console.WriteLine($"Running at {percent} %, set back to 100 %");
robot.Snpx.IntegerSystemVariables.Write("$MCR.$GENOVERRIDE", 100);
}
// Lock the +% and -% keys of the pendant, and unlock them later
robot.Snpx.SetVariable("$GENOV_ENB", false);
robot.Snpx.SetVariable("$GENOV_ENB", true);
}
}
Click to see the full code

The same variables can be read and written with CGTP, Telnet KCL or KCL over CGTP, see Read & write system variables. With the RMI option, GetStatus().SpeedOverride gives the override too, see RMI frames, I/O & status.

Watch it over a fleet

A line that runs at 80 % for weeks loses cycle time and nobody sees it. Read $MCR.$GENOVERRIDE of every robot once a minute and log it with the time. A robot that stays below 100 % in automatic production is a question for the shift leader, not always a fault: somebody may have slowed it down for a good reason.

For several values at each cycle, put them in one SNPX batch read, see Optimize with batch operations.

Cautions

  • The override is not a safety function. Do not use it to protect people: use the safety functions of the controller (DCS).
  • A PC that writes 100 % while an operator is in the cell, teaching at low speed, is a risk. Write it only in automatic mode, with the agreement of the people who run the line.
  • Unlock the keys ($GENOV_ENB back to TRUE) when your application stops. Otherwise the operator cannot slow down the robot from the pendant.
  • Stream Motion needs $MCR.$GENOVERRIDE at 100, see Stream Motion overview. Its own override is another thing, see Send trajectories.

See also

  • Fanuc system variables list
  • SNPX system variables
  • Telnet variables & I/O