Check the payload schedules

Read the payload schedules $PLST_GRP1 and the active schedule $PLST_PARNUM of every Fanuc robot, and find the schedules with no mass or no comment.

  • The variables
  • List the schedules of a robot
  • Audit a fleet
  • Write a payload
  • Cautions
  • Without code
  • See also

Does each Fanuc robot of the line run with the right payload? The payload schedules are the system variable $PLST_GRP1 and the active one is $PLST_PARNUM. One read per robot is enough to list them all, and to find a schedule that was never filled in.

The variables

VariableTypeMeaningFile
$PLST_GRP1[n]PLST_GRP_TPayload schedule n of group 1. The digit in the name is the motion group: $PLST_GRP2 for group 2symotn.va
$PLST_GRP1[n].$COMMENTSTRINGComment of the schedulesymotn.va
$PLST_GRP1[n].$PAYLOADREALMasssymotn.va
$PLST_GRP1[n].$PAYLOAD_X, _Y, _ZREALCentre of gravitysymotn.va
$PLST_GRP1[n].$PAYLOAD_IX, _IY, _IZREALInertiasymotn.va
$PLST_PARNUM[g]INTEGERActive payload schedule of group gsymotn.va

The SDK gives them with GetSymotnFile(): PlstGrp1 to PlstGrp5, and PlstParnum. The units are not given here: compare one schedule with the PAYLOAD screen of the pendant before you write a rule on the values.

In the listings we checked, both variables are read only (Access: RO). A program selects a schedule with the PAYLOAD[n] instruction.

List the schedules of a robot

parameters.Ftp.Enable = true;
robot.Connect(parameters);
// symotn.va holds the payload schedules: $PLST_GRP1[n] is PlstGrp1[n - 1]
SymotnFile motion = robot.Ftp.KnownVariableFiles.GetSymotnFile();
int active = motion.PlstParnum[0]; // $PLST_PARNUM[1]
Console.WriteLine($"Active schedule of group 1: {active}");
for (int n = 1; n <= motion.PlstGrp1.Length; n++)
{
PlstGrpVariableType s = motion.PlstGrp1[n - 1];
if (s == null) continue;
string warning = s.Payload <= 0 ? " <- no mass" : "";
Console.WriteLine($"{n} '{s.Comment}' PAYLOAD={s.Payload} X={s.PayloadX} Y={s.PayloadY} Z={s.PayloadZ}{warning}");
}
}
}
Click to see the full code

The .NET and Python arrays start at 0: $PLST_GRP1[1] is PlstGrp1[0], and $PLST_PARNUM[1] is PlstParnum[0].

Audit a fleet

Run the same read on every robot and keep a table: robot, schedule, comment, mass. Look for:

  • a schedule with a mass of 0 while the robot carries a tool,
  • a schedule without comment, that nobody can explain,
  • all the schedules with the same values, which can mean that they were never set,
  • a schedule that changed since the last audit.

Write a payload

With the RMI option (R912), SetPayloadValue writes the mass, the centre of gravity and the inertia of a schedule, and SetPayloadSchedule makes it active. The parameters of these calls are in kg, m and kg·m².

parameters.Rmi.Enable = true;
robot.Connect(parameters);
// Define payload for schedule 1: 5 kg, center of gravity offset 0.1 m in Z
robot.Rmi.SetPayloadValue(
scheduleNumber: 1,
massKg: 5.0f,
cgXm: 0f, cgYm: 0f, cgZm: 0.1f);
// Include inertia values
robot.Rmi.SetPayloadValue(
scheduleNumber: 2,
massKg: 3.0f,
cgXm: 0.05f, cgYm: 0f, cgZm: 0.08f,
inertiaXkgm2: 0.002f, inertiaYkgm2: 0.002f, inertiaZkgm2: 0.001f);
// Define payload compensation
robot.Rmi.SetPayloadCompensation(
scheduleNumber: 1,
massKg: 1.0f,
cgXm: 0f, cgYm: 0f, cgZm: 0.05f,
inertiaXkgm2: 0.001f, inertiaYkgm2: 0.001f, inertiaZkgm2: 0.0005f);
// Activate schedule 1 immediately (command, not a TP instruction)
robot.Rmi.SetPayloadSchedule(1);
robot.Disconnect();
}
Click to see the full code

See RMI frames, I/O & status.

Cautions

  • Enter the values of the real tool, from its drawing or from the payload identification of the controller.
  • A change of payload changes how the robot moves. Test the programs at low speed after a change.

Without code

TouchUp, the robot workbench for VS Code, shows the payload schedules 1 to 10 of a connected Fanuc controller, with the number, the comment and the load, in its User Frames and Tools view. It reads them only. See User frames and tools.

See also

  • Fanuc system variables list
  • Tool frames: $MNUTOOL and $MNUTOOLNUM
  • Diagnostics & variables (FTP)