Read and reset alarms

Detect an alarm of a Yaskawa controller, read its code and text, reset it and check the result, from C# or Python.

  • Prerequisites
  • Alarm or error
  • Example
  • Before the reset
  • Troubleshooting
  • What to read next

This article shows how to detect an alarm of a Yaskawa Motoman controller from a PC, read its code and its text, and reset it, in C# or Python. It gives a complete program that checks the result of the reset.

Prerequisites

  • The SDK is connected to the controller: see Connect to your robot.
  • To reset, the controller accepts the remote commands. Reading the alarms works in any mode.

Alarm or error

StateDetectClear
Alarm: the controller stopsGetStatusInformation().AlarmingAlarmReset(AlarmResetType.Reset)
Error: a message on the pendantGetStatusInformation().ErrorOccurringAlarmReset(AlarmResetType.Cancel)

GetAlarm reads the code, the sub code, the time and the text of each alarm. GetAlarmExtended adds the texts of the sub codes.

Example

using UnderAutomation.Yaskawa;
using UnderAutomation.Yaskawa.HighSpeedEServer;
public class HowToReadResetAlarms
{
static void Main()
{
var robot = new YaskawaRobot();
robot.Connect("192.168.0.1");
RobotStatusData status = robot.HighSpeedEServer.GetStatusInformation();
if (status.Alarming || status.ErrorOccurring)
{
// 1. Read the alarms, the latest first
foreach (RobotRecentAlarm which in Enum.GetValues(typeof(RobotRecentAlarm)))
{
RobotAlarmData alarm = robot.HighSpeedEServer.GetAlarm(which);
if (alarm.Code != 0)
Console.WriteLine($"{alarm.OccurringTime} {alarm.Code} {alarm.Text}");
}
// 2. Remove the cause on the cell, then reset
robot.HighSpeedEServer.AlarmReset(status.Alarming ? AlarmResetType.Reset : AlarmResetType.Cancel);
// 3. Check that the alarm is gone
status = robot.HighSpeedEServer.GetStatusInformation();
Console.WriteLine(status.Alarming ? "The alarm is still active" : "Alarm reset");
}
robot.Disconnect();
}
}

The program:

  1. reads the status, and stops if there is no alarm and no error;
  2. prints each alarm reported by the controller, the most recent first;
  3. resets the alarm, or cancels the error;
  4. reads the status again to check that the alarm is gone.

Before the reset

A reset does not remove the cause of the alarm. If the cause is still present, the alarm comes back at once. Log the code and the text before the reset, and let an operator check the cell when the alarm concerns safety or a collision.

Troubleshooting

  • The reset is refused: the remote mode is off. See Prepare the controller.
  • The alarm comes back: its cause is still present. Look for the code in the alarm manual of your controller.
  • Code is 0: there is no alarm at this position of the list.